Kit, air check is the perfect solution to check the quality of your compressor, monitor, dewpoint, relative, humidity, temperature and more important. Check the quality of your compress air if it’s free from impurities, oil, or other particles with the magnifier.
No se pudo cargar la disponibilidad de recogida
Free standard shipping on orders over $200
HUMIDITY
for solvent-based paints, the correct value is between 10% and 15%;for water-based
paints, the correct value is between 5% and 10%;for clear coats, the correct value is between 10% and 15%. Above these values, the humidity of the air compromises the distension of the solvent base, affects the gloss and flash-off times of the solvent base, and causes speckles in the clear coat. We recommend using FSRD3-FSRD4 filters or TD³PRO Thermoconditioner, which bring the humidity to 0%.
TEMPERATURE
Temperatures below 25°C / 77°F cause a thermal shock that is harmful for water-based paints and make the application of clear coats and solvent-based paints more difficult. This is because, due to adiabatic expansion, the expanded air loses approximately 15°C / 59°F. Detecting an air temperature at 20°C / 68°F is equivalent to applying at about 5°C / 41°F, with the consequences mentio- ned above. We recommend using the Thermodry Technology TD³PRO /TD¹PRO which brings the temperature up to 50°C / 122°F for clear coat and 40°C/104°F for base.
DEW POINT
for solvent-based paints, the correct value is between -6°C / 21.2°F and -12°C / 10.4°F ;for water-based paints, the correct value is between -15°C/ 5°Fand -20°C / -4°F;for clear coats, the correct value is between -6°C / 21.2°F and -12°C / 10.4°F.
The further you move away from these values, the less risk there is of water vapour transforming from a vaporous state to a liquid state, thus generating additional water in the system. We recommend using FSRD3-FSRD4 filters or Thermodry Technology TD³PRO, which bring the dew point to -40°C/ -40°F/-50°C /122°F
AIR CLEANING
The analysis of the filter inside the cartridge must give a result of perfect air cleaning. The presence of black dots or a change in color of the filter indicates a clear state of air contaminated by impurities and/or oil which, inevitably, leads to compromising the final painting result. In this case we recommend using Walcom® FSRD - TD range filter systems or replacing the filter cartridges of existing filter systems.
| n° 1 AIR CHECK | with hook for DGT T-RH and test card holder |
| n° 1 DGT T-RH | humidity, temperature and dew point meter |
| n° 1 lens | for evaluating impurities on test paper |
| n° 1 set | of test papers + DGT T-RH protective filters |
| Weight | 198 g |